EU Releases New Draft of ErP and Energy Efficiency Label Regulations for Air Conditioners, Heat Pumps and Comfort Fans

EU Releases New Draft of ErP and Energy Efficiency Label Regulations for Air Conditioners, Heat Pumps and Comfort Fans

The EU has issued a new draft of ErP and energy efficiency labeling regulations for air-to-air air conditioners, heat pumps and comfort fans, which will replace the existing (EU) No 206/2012 and (EU) No 626/2011 directives in the future. The new draft stipulates that the implementation date of the new ErP and energy efficiency label is January 1, 2022. However, from September 1, 2021, suppliers (local manufacturers and importers) must register product information in the product database and provide new labels to dealers.

Key points of the new draft

Applicable objects: air to air air conditioners and air to air heat pumps with rated power ≤ 12kW and comfort fans with rated power ≤ 125W using mains power for refrigeration and/or heating.

Major changes:

1. The evaluation of energy efficiency grade and minimum energy efficiency requirements of mobile air conditioners has changed from the original EER and COP to the seasonal SEER and SCOP, and the capacity test under partial load conditions has been added.

2. For mobile single duct air conditioners and heat pumps, the influence of indoor heat leakage caused by product characteristics is considered when calculating SEER and SCOP.

3. The rated capacity test condition of mobile single duct air conditioner changes, and the indoor dry/wet bulb temperature changes from 35oC/24oC to 27oC/19oC.

4. The following functional requirements are added to the mobile air conditioner:

(1) Mobile air-to-air heat pumps shall include an auxiliary heater with maximum auxiliary heater capacity

(elbu_max) ≥ elbu (Tdesignh); (2) The mobile single duct heat pump shall include an outdoor temperature sensor, which can control the heat pump and auxiliary heater according to the outdoor temperature.

5. The energy efficiency grade and minimum energy efficiency requirements are determined based on “seasonal space cooling energy efficiency” and “seasonal space heating energy efficiency”: (1) η s. C “Seasonal space cooling energy efficiency”, expressed as a percentage (%) calculated by SEER; (2) η s. H “Seasonal space heating energy efficiency”, expressed as a percentage (%) calculated by SCOP.

Among them,

η s,c (%) = SEER / 2.1 x 100 – 3

η s,h (%) = SCOP / 2.1 x 100 – 3

The power consumption limit of mobile single duct, double duct air conditioners and comfort fans to be turned off will not be assessed separately.

6. Add the minimum energy efficiency (SV) requirements and noise limit requirements for comfort fans.

7. The classification of energy efficiency label becomes A-G.

8. Add requirements for comfort fan energy efficiency label.

  • Implement noise energy efficiency rating A-D.

Energy efficiency requirements:

  • From January 1, 2022, the seasonal space cooling energy efficiency of air air conditioners shall not be lower than the limit value in Table 1:
 ηs,c ( %) 
Mobile air air conditioner107 
Fixed double duct/single duct air conditioner, rated power<6 kW202 
Fixed double duct/single duct air conditioner, rated power ≥ 6 kW185 
Other fixed air-to-air air conditioners, rated power<6 kW283 
Other fixed air air conditioners, rated power ≥ 6 kW259 

(2) From January 1, 2022, the seasonal space heating energy efficiency of air-to-air heat pump shall not be lower than the limit value in Table 2:

 ηs,h (%)
Mobile single duct heat pump46
Mobile double duct heat pump48
Fixed double duct/single duct heat pump, rated power<6 kW134
Fixed double duct/single duct heat pump, rated power ≥ 6 kW131
Other fixed air-to-air heat pumps, rated power<6 kW187
Other fixed air-to-air heat pumps, rated power ≥ 6 kW183

(3) From January 1, 2022, the ‘service value’ (SV value) of the comfort fan shall not be lower than the limit value in Table 5:

 SV (m3/min)/W
All comfort fans except ceiling fans, fan diameter ≥ 20 and<25 cm0,5
All comfort fans except ceiling fans, fan diameter ≥ 25 and<30 cm0,65
All comfort fans except ceiling fans, fan diameter ≥ 30 and<40 cm0,75
All comfort fans except ceiling fans, fan diameter ≥ 40 and<50 cm1,08
All comfort fans except ceiling fans, fan diameter ≥ 50 and<60 cm1
All comfort fans except ceiling fans, fan diameter ≥ 60 cm1,1
Ceiling fan, fan diameter>0 and<60 cm1,4
Ceiling fan, fan diameter>60 and<90 cm2,6
Ceiling fan, fan diameter ≥ 90 and<120 cm3,1
Ceiling fan, fan diameter ≥ 120 and<140 cm4,0
Ceiling fan, fan diameter ≥ 140 and<150 cm4,1
Ceiling fan, fan diameter ≥ 1504,3

Sound power:

From January 1, 2022, the sound power of air-to-air air conditioners, air-to-air heat pumps and comfort fans shall not exceed the limits in Table 6:

 Sound power level dB (A) 
indoor
Air to air air conditioners and air to air heat pumps other than single duct and double duct, rated power<6 kW60 65 
Other air-to-air air conditioners and air-to-air heat pumps except single duct and double duct, rated power ≥ 6 kW65 70 
Single and double duct air conditioners and heat pumps65 – 
All comfort fans except ceiling fans, fan diameter ≥ 20 and<23 cm59 – 
All comfort fans except ceiling fans, fan diameter ≥ 23 and<25 cm60 – 
All comfort fans except ceiling fans, fan diameter ≥ 25 and<30 cm61 – 
All comfort fans except ceiling fans, fan diameter ≥ 30 and<35 cm63 – 
All comfort fans except ceiling fans, fan diameter ≥ 35 and<40 cm65 – 
All comfort fans except ceiling fans, fan diameter ≥ 40 and<45 cm67  
All comfortable fans except ceiling fans, fan diameter ≥ 45 and<50 cm68 – 
All comfortable fans except ceiling fans, fan diameter ≥ 50 and<60 cm70 – 
All comfortable fans except ceiling fans, fan diameter ≥ 60 cm73 – 
Ceiling fan, fan diameter>0 and<90 cm62 – 
Ceiling fan, fan diameter ≥ 90 and<120 cm65 – 
Ceiling fan, fan diameter ≥ 120 and<130 cm67 – 
Ceiling fan, fan diameter ≥ 130 and<140 cm70 – 
Ceiling fan, fan diameter ≥ 140 and<150 cm72 – 
Ceiling fan, fan diameter ≥ 15075 – 

Classification of energy efficiency:

(1) The energy efficiency grade of air conditioner is shown in the following table:

Energy efficiency gradeSeasonal space cooling energy efficiency( η s,c) (%)
A(highest grade)ηs,c ≥460
B330 ≤ηs,c < 460
C240 ≤ηs,c < 330
D180 ≤ηs,c < 240
E130 ≤ηs,c < 180
F90 ≤ηs,c  < 130
G (lowest energy level)ηs,c < 90

(2) The energy efficiency grade of air to air heat pump is shown in the following table:

Energy efficiency gradeSeasonal space cooling energy efficiency(ηs,h) (%)
A(highest grade)ηs,h ≥ 250
B200 ≤ηs,h < 250
C160 ≤ηs,h < 200
D130 ≤ηs,h < 160
E100 ≤ηs,h < 130
F80 ≤ηs,h  < 100
G (lowest energy level)ηs,h < 80

(3) The energy efficiency level of comfort fan is shown in the following table:

Energy efficiency gradeSeasonal space cooling energy efficiency grade(SV) ((m3/min)/W)
A (highest grade)SV ≥ 6
B5 ≤ SV < 6
C4 ≤ SV < 5
D3 ≤SV < 4
E2 ≤ SV < 3
F1 ≤ SV < 2
G (lowest energy level)SV < 1

(4) The sound power levels of air-to-air air conditioners, air-to-air heat pumps and comfort fans are shown in the following table:

Energy efficiency level sound power(dB(A))
A< 45
B ≥ 45 and<55
C ≥ 55 and<65
D≥ 65
EU Releases New Draft of ErP and Energy Efficiency Label Regulations for Air Conditioners, Heat Pumps and Comfort Fans

UnitedStar Introduction

As an industry leader, fan and ac manufacturer UnitedStar has a strong production capacity of more than 16000 fans per day. Our factory covers an area of 47200m²  with BSCI and ISO9001, and have advanced automated production lines in which robots assemble components. The Annual output exceeds 10 million units. With over 14 years’ R & D experience, all kinds of fans are available from fan company UnitedStar, including standing fans, ceiling fans, DC fans, table fans and portable ac, etc. Every year our products enjoy a good reputation all over China and are exported to every corner of the world. We believe that it is because we insist on quality first, making sure that all of our products meet international standards. China electric fan factory UnitedStar also provides customized service for customers who want their own brand or logo on their fans. If you need any help with choosing a suitable product or have any questions about us, please feel free to contact us at any time and we will try our best to assist you. Please be assured that your inquiry will be replied to within 24 hours.

WeChat

null

Thank you for your message!

The message was successfully sent,  The team will contact you as soon as possible after receiving it!

Thank you for your message!

The message was successfully sent,  The team will contact you as soon as possible after receiving it!

Get Quote